Research Article: Pacing during TAVR through a coronary wire in the coronary artery and left ventricular wire
Abstract:
The conventional pacing-over-the-wire technique in transcatheter aortic valve replacement (TAVR) results in high impedance and voltage thresholds, which may cause loss of capture and valve embolisation. Our team reported that coronary wire pacing, in which a coronary wire is placed in the left coronary artery (anode) and a left ventricular wire (cathode), is associated with extremely low impedance and pacing voltage thresholds in patients who are at high risk of coronary obstruction. Moreover, coronary wire pacing is simple and reliable. In this study, we illustrate the coronary wire pacing technique in a patient to provide a new approach to wire pacing in TAVR.
Introduction:
The safety and efficacy of guidewire pacing compared with right ventricular pacing in transcatheter aortic valve replacement (TAVR) have been validated ( 1 ). The use of coronary guidewire pacing during coronary angioplasty has also been reported for the last more than 40 years ( 2 ). However, whether left ventricular guidewire and coronary guidewire pacing can be applied in TAVR patients with coronary risk who require coronary protection has not been reported to date. In this study, we compared the impedance and…