why choose us

300×250 Ad Slot

Research Article: Boundary-stratified safety evaluation of large language models for clinical decision support: a synthetic benchmark in chronic kidney disease renoprotective therapy

Date Published: 2026-11-03

Abstract:
Large language models (LLMs) are increasingly proposed for medication-review support, but their behaviour at guideline-uncertain decision boundaries is rarely examined. Aggregate accuracy can hide model-specific divergence at such boundaries. We characterised boundary-zone rule adherence, replicate-query reproducibility, and reasoning-error rate of four frontier LLMs reviewing renoprotective-therapy omissions across the chronic kidney disease (CKD) severity spectrum. We constructed 100 synthetic CKD vignettes (G3a–G5D; 75 with prespecified omissions, 25 decoys). Four LLMs were queried three times each at temperature 0 (1,200 calls). Omission criteria were operational adaptations of KDIGO 2024. They included an investigator-defined rule for de novo renin–angiotensin system inhibitor (RASi) initiation at eGFR < 15, a zone not covered by KDIGO 2024 recommendations. Two nephrologists applied the criteria to a stratified 20-case subset. In a post hoc analysis, every boundary non-detection was re-read and its stated rationale coded, and sensitivity was recomputed under a KDIGO-concordant reference standard. All models detected 97%–100% of SGLT2 inhibitor and finerenone omissions. At the eGFR < 15 RASi boundary ( n = 20), adherence to the operational rule was 85% (Grok 4.1 Fast), 55% (GPT-5.4), 10% (Gemini 3.1 Pro), and 10% (DeepSeek R1). All 48 non-detections stated an explicit reason. GPT-5.4 withheld RASi only in the 9 dialysis-dependent cases and detected all 11 non-dialysis cases. Gemini and DeepSeek also withheld RASi in non-dialysis G5, citing hyperkalaemia or acute kidney injury risk. In a post hoc analysis excluding the 20 boundary cases, sensitivity was 96.5%–100% for every model. Rubric-application agreement was perfect (kappa = 1.000). Reasoning-defect rates ranged from 0% (GPT-5.4) to 27% (DeepSeek R1), and replicate Jaccard similarity from 0.74 to 0.93. Between-model differences were concentrated where guidelines are silent. There, models applied distinct and explicitly stated decision policies rather than overlooking the drug class. Lower adherence to the study rule should not be read as lower clinical safety. Pre-deployment evaluation of clinical LLMs should report boundary-stratified behaviour, replicate reproducibility, and reasoning errors alongside aggregate accuracy, and should be validated against real-world prescribing.

Introduction:
Clinical artificial-intelligence tools are being adopted for medication-review support faster than evaluation standards are developing. A large language model (LLM) with high aggregate accuracy on a benchmark may be treated as safe by downstream quality-assurance processes. Aggregate measures, however, can conceal behaviour that is concentrated in narrow clinical subgroups. Subgroup-concentrated failures have repeatedly been hidden inside apparently well-performing clinical AI. Racial bias in pulse oximetry…

Read more

300×250 Ad Slot